ESE Lightning Arrester
The lightning protection system shall be of the enhanced type which is
designed to attract lightning to a preferred point and safely convey the
lightning energy to ground with minimal risk of side flashing via a predetermined
route.
As per NF C 17 – 102, the ESE air terminal should be tested with the “Switching Impulse Voltage” of 700 KV & “Direct Voltage” of 70 KV.
Lightning Counter
The Lightning systems shall be installed complete with the lightning strike recorder. The lightning strike recorder shall contain a mechanical 6 digit display which
will register all lightning discharges with a sensitivity of 1500A 8/20 µs peak
current impulse.As per IEC 60-1:1989, the lightning strike recorder should withstand a maximum current impulse equivalent to 450 KA (8/20 micro sec waveform)
Earthing Electrode
We are happy to inform you that we are representing Earthing Electrode maintenance free chemical gel earthing electrodes for all electrical application. Galaxy earth electrodes is an ISO 9001:2000 certified, CPRI (Central Power Research Institute) tested & certified, maintenance free, eco friendly, long lasting, fool proof earthing solution which is an one time investment for the electrical safety of your valuable instruments & human beings.
Earthing Compound Gel
The chemical earth electrode shall be highly conductive and non-corrosive. The chemical earth electrode system with adequate Moisture Booster should give low earth resistance value of < 2 ohms with single electrode and < 1 ohm with Tri-Pod earthing. Moisture Booster should be of specially developed electrolytic gel which should be of highly conductive.